CVD / CVI coating and infiltration systems

Type CVD 900

Functions:

  • Useful dimensions   (Ø/h) :    900 mm / 1400 mm 
  • Useful volume :   900 dm³
  • max. loading capacity :   ≤ 400 kg
  • Process temperature range :   900 - 1500 °C
  • max. temperature :    1600°C
  • Median heating rate  (RT-1600°C) :   ≤ 5 K/ min
  • Temperature homogeneity in useful volume :   ± 10 K
  • Ultimate vacuum (cold, clean furnace) :   ≤ 2x10-1 mbar (20 Pa)
  • Leakage rate :   ≤ 5 x 10-2 mbar l / s
  • Partial pressure control range :   10 - 100 mbar
  • max. available heating power :   300 KW
  • Cooling water requirement (p_in: 4 bar) :   120 KW
  • Space requirement (W/H/D) :   8,6 / 7,5 / 5 m
  • Needed power supply :   3 x 380 V±5%, 50 Hz, 400 kVA
  • control system :   Siemens S7 / 1500 and WinCC
  • Option: Burner Scrubber
  • Option: Vaporizer

reserves the right to make changes

CVD systeme: chemical vapor deposition
magnify

CVD systeme: chemical vapor deposition

Typ: KCE®-FCT CVD 900-SiC

We use cookies to offer you a better browsing experience, personalise content and ads, to provide social media features and to analyse our traffic. Read about how you can control cookie usage by clicking Settings. You consent to our cookies if you continue to use this website.

Please choose which type of cookies you consent to:

(ie. account login related cookies)
(i.e. facebook)
(i.e. youtube)
(ie. Google Analytics)

further information 

loading
loading