CVD / CVI coating and infiltration systems

Type CVD 30

Functions:

  • Useful dimensions   (Ø/h) :    360 mm / 295 mm 
  • Useful volume :   30 dm³
  • max. loading capacity :   ≤ 25 kg
  • Process temperature range :   900 - 1500 °C
  • max. temperature :    1600°C
  • Median heating rate  (RT-1600°C) :   ≤ 5 K/ min
  • Temperature homogeneity in useful volume :   ± 10 K
  • Ultimate vacuum (cold, clean furnace) :   ≤ 2x10-1 mbar (20 Pa)
  • Leakage rate :   ≤ 5 x 10-2 mbar l / s
  • Partial pressure control range :   10 - 100 mbar
  • max. available heating power :   45 KW
  • Cooling water requirement (p_in: 4 bar) :   30 KW
  • Space requirement (W/H/D) :   5 / 3 / 3 m
  • Needed power supply :   3 x 380 V±5%, 50 Hz, 130 kVA
  • control system :   Siemens S7 / 1500 and WinCC
  • Option: Burner Scrubber
  • Option: Vaporizer